SEN CENTRIFUGAL PUMP MONOBLOC Centrifugal Pump
Close-coupled single-stage, end-suction, vertical discharge type centrifugal electric pump
Scope of supply
Pump supplied with bare shaft pump with motor, in horizontal design, painted to plant standard, sealed by a soft-packed stuffing box or by a mechanical sea, without coupling. (Electric Pump)
Add-on components to convert the pump to a complete pump / motor set:
Pump to be supplied with:
- Close-coupled centrifugal pump (for horizontal installation)
Guarantee, testing and quality control
Every pump is tested for correct functioning. The operating data are guaranteed without acceptance test in accordance with ISO 9906 Annex A, DIN 1944/III or comparable international testing standards.
Order data
- Electric Pump:
- Description of the pump according to "Designation"
- Capacity Q
- Total head H ( Hgeo and plant losses )
- Material combination
- Mating dimensions of flanges
- Mechanical seal material (Primary ring / Mating ring / Secondary seal / Others)
- Liquid handled and liquid temperature
- Accessories required
- Number of copies and language of operating manual
- Motor:
- Type of construction
- Type of enclosure
- Voltage, frequency, method of starting
- Ambient temperature
- Insulation class
- Accessories required
Pump description
The close-coupled centrifugal electric pump is designed for the pumping of cold water or any clear liquids which do not contain solids and are not corrosive, abrasive or explosive when in contact with the pump motor unit and its working parts
The SEN pump is a close-coupled single-stage centrifugal electric pump with an axial inlet and a vertical outlet. The dimensions of the volute pump casing, the suction and discharge diameters, and the casing feet correspond to the standards: DIN 24255 and NF EN 733.
Construction features
• Main dimensions: Apply to EN733 (DIN24255) standard and back pull out type
• Casing structure: End suction, center radial discharge
• Flange pressure rate: ISO7005.2 PN1.6MPa
• Shaft seal : Single mechanical seal ( Graphite / Ceramic / NBR / SS304), According to Standard EN 12756
On request: Graphite / Silicon carbide / FPM / SS316
• Driven shaft: Pump and motor flanged together to form a close-coupled unit, with common shaft.
Operation conditions
• Working Temperature Range: -10ºC ~ +90ºC
• Max. Allowable Working Pressure (MAWP): 10bar
Hydrostatic Test Pressure = 1.3 times the maximum discharge pressure, but not exceed 13 bar.
Pump specifications
• Discharge flange diameter: DN32 - DN80 mm
• Capacity Q range: 4.5m3/h - 240m3/h (50Hz)
• Head H range: 10m - 92.5m
• Operating speed: 2900RPM (50Hz) 3550 (60Hz)
Motor specifications
• Totally Enclosed Fan Cooled asynchronous induction motor
• Degrees of motor protection: IP55 (IEC60034-5)
• Insulation Class: F
• Degrees of motor protection: IP55 (IEC60034-5)
• Duty: S1 continuous duty operation
• Altitude shall not exceed 1000m above seal-level (IEC60034-1)
• Allowed air temperature between -20ºC and 40ºC (IEC60034-1)
• Winding: (On request: Motor winding is protected with 3 PTC thermistors for tripping)
3 Phase | 2 - 4HP | 220-240VD / 380-420VY - 50Hz |
5.5 - 50HP | 380-420VD / 660-725VY - 50Hz | |
1 Phase | 2 - 2HP | 220V - 50Hz / 240V - 60Hz |
Pump model: SEN 50-200B | |
SEN | HydroBlue EN733 standard pump |
50 | Discharge flange diameter: DN50 (mm) |
200 | Nominal diameter of impeller: Φ200mm |
B | Times of cutting for impeller: A is the first time, B is the second time |
Part Description | Materials Class |
USA | Germany | Japan |
AISI , ASTM | DIN | JIS | ||
Casing | Cast iron | Class 25B | GG-20 | FC200 |
Austenitic Stainless steel |
CF-8, SS30 | DIN 1.4308 | SUS304 | |
CF-8M, SS316 | DIN 1.4408 | SUS316 | ||
Impeller | Cast iron | Class 25B | GG-20 | FC200 |
Austenitic Stainless steel |
CF-8, SS304 | DIN 1.4308 | SUS304 | |
CF-8M, SS316 | DIN 1.4408 | SUS316 | ||
Bronze | C83600 | G-CuSn5ZnPb | BC6 | |
Shaft | Carbon steel | 1045 | C45 | S45C |
Martensite Stainless steel |
AISI420 | DIN1.4021 | SUS410J1 | |
Austenitic Stainless steel |
AISI304 | DIN1.4301 | SUS304 | |
Motor bracket | Cast iron | Class 25B | GG-20 | FC200 |
Shaft seal | Single mechanical seal Material: Graphite / Ceramic / NBR / SS304, According to Standard EN 12756 On request: Graphite / Silicon carbide / FPM / SS316 |
Motor nameplate rating | Percentages of rated pump power (%) |
|
(KW) | (HP) | |
< 22 | < 30 | 125 |
≥22 ~ 55 | ≥30 ~ 75 | 115 |
≥ 55 | ≥ 75 | 110 |
For higher coolant temperatures and / or site altitudes higher than 1000 m above seal level, the specified motor output must be reduced.
Revise as shown in the picture below:
Vibration
In the operating range of 0.6 to 1.2 x QOpt: Veff ≤ 4.5 mm/s
- Qopt ----- Pump operating point
Noise
According to ISO 3746
Attention must be given to the exposure of personnel to the noise, and local legislation will define when guidance to personnel on noise limitation in required, and when noise exposure reduction is mandatory. This is typically 80 to 85 dBA.
The usual approach is to control the exposure time to the noise or to enclose the machine to reduce emitted sound.
You may have already specified a limiting noise level when the equipment was ordered, however if no noise requirement were defined, then attention is drawn to the following table to given an indication of equipment noise level so that you can take the appropriate action in your plant.
Pump noise level is dependent on a number of operational factors, flow rate, pipework design and acoustic characteristics of the building, and so the values given are subject to a 3 dBA tolerance and cannot be guaranteed.
Pump noise data sheet
Motor size and speed kW |
A typical sound pressure level of 1 meters from the equipment, LpA, (dBA) | |||||||
3550 rpm | 2900 rpm | 1750 rpm | 1450 rpm | |||||
Pump only | Pump and motor | Pump only | Pump and motor | Pump only | Pump and motor | Pump only | Pump and motor | |
< 0.55 | 72 | 72 | 64 | 65 | 62 | 64 | 62 | 64 |
0.75 | 72 | 72 | 64 | 66 | 62 | 64 | 62 | 64 |
1.1 | 74 | 74 | 66 | 67 | 64 | 64 | 62 | 63 |
1.5 | 74 | 74 | 66 | 71 | 64 | 64 | 62 | 63 |
2.2 | 75 | 76 | 68 | 72 | 65 | 66 | 63 | 64 |
3 | 75 | 76 | 70 | 73 | 65 | 66 | 63 | 64 |
4 | 75 | 76 | 71 | 73 | 65 | 66 | 63 | 64 |
5.5 | 76 | 77 | 72 | 75 | 66 | 67 | 64 | 65 |
7.5 | 76 | 77 | 72 | 75 | 66 | 67 | 64 | 65 |
11 | 80 | 81 | 76 | 78 | 70 | 71 | 68 | 69 |
15 | 80 | 81 | 76 | 78 | 70 | 71 | 68 | 69 |
18.5 | 81 | 81 | 77 | 78 | 71 | 71 | 69 | 71 |
22 | 81 | 81 | 77 | 79 | 71 | 71 | 69 | 71 |
30 | 83 | 83 | 79 | 81 | 73 | 73 | 71 | 73 |
37 | 83 | 83 | 79 | 81 | 73 | 73 | 71 | 73 |
45 | 86 | 86 | 82 | 84 | 76 | 76 | 74 | 76 |
55 | 86 | 86 | 82 | 84 | 76 | 76 | 74 | 76 |
75 | 87 | 87 | 83 | 85 | 77 | 77 | 75 | 77 |
90 | 87 | 88 | 83 | 85 | 77 | 78 | 75 | 78 |
110 | 89 | 90 | 85 | 87 | 79 | 80 | 77 | 80 |
132 | 89 | 90 | 85 | 87 | 79 | 80 | 77 | 80 |
200 | 85 | 87 | 83 | 85 | ||||
315 | 87 | 90 | 85 | 86 |
Note:
1. Noise levels within this range may require noise control.
2. The noise level of the greater motor power shall be discussed by the purchaser and the manufacturer / supplier.
Q1: Are you a factory or a trading company? A: We are a professional service provider of customized complete solutions in the field of fluid machinery and fluid engineering. Q2: What're your payments? A: L/C, T/T, D/P, PayPal, Western Union, Small-amount payment Q3: What about package? A: Standard exportation packaging with polywood box. Q4: How about the delivery time? A: 30~90 days, Depend on quantity and season. Q5: How about the MOQ? A: 1 set. Q6: How about the quality guarantee? A: One year after commissioning or 18 months after delivery. |